SPECIALTY APPLICATIONS
Advanced Foundation Repair can engineer solutions for difficult
problems and unusual situations. For Example:
Lightly reinforced slabs. In some instances, the best
approach is to lift the perimeter with pilings and to lift
the
interior with polyurethane injection. Polyurethane injection
can be used to lift very light structures without tunneling
underneath or cutting holes in floors. Our companies have
used this approach frequently in Amarillo.
Severed reinforcing cables: In one instance, all but one
of
the reinforcing cables in a foundation had been severed.
Before lifting the building, it was necessary to bolt an
external steel reinforcing system to the foundation.
|
|